The Point Sensor Definition allows users to select which time-domain data to collect. A definition must accompany a point sensor, which specifies a vertex location in the simulation space at which the data is collected.

Users can access the Point Sensor Definition Editor by either right-clicking on the Definitions branch of the Project Tree and selecting New Point Sensor Definition, or double-clicking on an existing definition in the Project Tree.

Screenshot of the Point Sensor Definition Editor.

The Fields to Save options determine which output to save by allowing users to select one or more of the following Field vs Time options:

Users should note that the scattered fields are collected only when using a plane wave excitation and the scattered-field formulation is specified when creating an FDTD simulation. Poynting vector is an available result when both E and H versus time are collected.

The Sampling Time Range settings specify when cell edge data is saved to disk and made available for graphing. Users can either enter the desired Start Time and End Time, or check Start of Simulation and End of Simulation to assign the sampling time range to the simulation's beginning and ending values, respectively. Users can either enter a value for the Sampling Interval, which determines how often data is sampled within the time range, or check the Use Project Value option to define the Sampling Interval using the value in the advanced tab of the project properties editor. By default, XF selects a sampling rate that prevents aliasing if a fast-fourier transform (FFT) is applied to the time-domain output.

Four buttons provide options for completing changes to the editor: